FUZKK AUTO OCM
RUEN
CATALOG

Utility catalog

Filter by profile, task, standard and keywords.

38
Industrial OCM

Centrifuge Sediment Screen

Checks measured sediment volume as an indicator of contamination and insoluble products.

ASTM D1796
Open and run →
Industrial OCM

Compressor Oil Carbon Residue

Checks carbon residue as an indicator of deposit tendency in compressor service.

ASTM D189ASTM D524ISO 6615
Open and run →
Industrial OCM

Compressor Oil Gas Reactivity

Tracks change in acid number or another accepted indicator after exposure to process gas.

Open and run →
Industrial OCM

Copper Strip Corrosion

Checks the numeric corrosion class against the accepted product limit.

ASTM D130ISO 2160
Open and run →
Industrial OCM

Engine Oil Glycol Contamination

Screens coolant ingress using measured glycol content.

ASTM D2982
Open and run →
Industrial OCM

Environmentally Acceptable Hydraulic Fluid Condition

Screens HETG/HEPG/HEES/HEPR fluids using viscosity, water and TAN with configurable limits.

ISO 15380:2023
Open and run →
Industrial OCM

Extended Worked Penetration Change

Assesses grease mechanical stability using penetration change after extended working.

ASTM D217ISO 2137ISO 12924:2023
Open and run →
Industrial OCM

Ferrography Severity Screen

Combines large and small ferromagnetic particle indicators into a transparent triage index.

ASTM D7684-24ASTM D7690-24
Open and run →
Industrial OCM

Fire-Resistant Hydraulic Fluid Condition

Configurable screening of viscosity, composition/water and acid number for fire-resistant hydraulic fluids.

ISO 12922:2020ISO 7745:2024
Open and run →
Industrial OCM

Four-Ball Wear Scar

Checks wear-scar diameter against the fresh lubricant specification.

ASTM D4172ISO 20623
Open and run →
Industrial OCM

Gearbox Health Index

Combined Fe, PQ, viscosity, water and TAN screen for gearboxes.

ISO 12925-1:2024ANSI/AGMA 9005-F16
Open and run →
Industrial OCM

Grease Dropping Point

Compares measured dropping point with the minimum product or application limit.

ASTM D566ASTM D2265ISO 2176
Open and run →
Industrial OCM

Grease Water Washout

Compares grease mass loss in water washout with configured limits.

ASTM D1264ISO 12924:2023
Open and run →
Industrial OCM

Hydraulic Cleanliness Trend

Compares the three ISO 4406 codes with the previous sample and flags worsening cleanliness.

ISO 4406ISO 11500ISO 12669:2017
Open and run →
Industrial OCM

Hydraulic Viscosity Deviation

Compares in-service hydraulic-fluid viscosity against the fresh-fluid baseline.

ASTM D445
Open and run →
Industrial OCM

Hydraulic Water Saturation

Evaluates relative water saturation using thresholds configured for the fluid and temperature.

ASTM D6304 context
Open and run →
Industrial OCM

ISO 4406 Cleanliness Code

Checks the three cleanliness codes against the target profile for the component.

ISO 4406ISO 12669:2017ISO 11500
Open and run →
Industrial OCM

Karl Fischer Water Screen

Checks water against limits configured for the lubricant and asset.

ASTM D6304ISO 12937
Open and run →
Industrial OCM

Membrane Patch Colorimetry

Screens varnish potential using measured MPC/ΔE and configured limits.

ASTM D7843
Open and run →
Industrial OCM

NLGI Consistency Screen

Assesses measured grease penetration deviation from the target.

ASTM D217ISO 2137ISO 6743-9
Open and run →
Industrial OCM

Oil Dielectric Constant Deviation

Compares current value with baseline and flags abnormal composition change or contamination.

ASTM D924
Open and run →
Industrial OCM

Oil Foaming Characteristics

Checks foam volume and collapse time for the selected test sequence.

ASTM D892ISO 6247
Open and run →
Industrial OCM

Oil Insolubles Screen

Checks pentane or toluene insolubles against the method and asset profile.

ASTM D893ASTM D4055
Open and run →
Industrial OCM

Phosphate-Ester EHC Fluid Condition

Configurable acid-number, water and electrical-resistivity screen for phosphate-ester EHC fluid.

ASTM D8323-24ISO 11365:2025ISO 10050:2024
Open and run →
Industrial OCM

RPVOT / RULER Consistency

Combines remaining oxidation stability and antioxidant reserve for turbine-oil trending.

ASTM D2272ASTM D6971ASTM D2272-22
Open and run →
Industrial OCM

RPVOT Retention

Compares in-service and fresh-oil RPVOT for trend assessment of oxidation stability.

ASTM D2272
Open and run →
Industrial OCM

RULER Antioxidant Retention

Calculates antioxidant reserve relative to fresh oil.

ASTM D6971-22ASTM D7590-22
Open and run →
Industrial OCM

Transformer Acetylene Generation Rate

Calculates C₂H₂ change rate between consecutive DGA samples for trend monitoring.

IEEE C57.104IEC 60599
Open and run →
Industrial OCM

Transformer Oil DGA Screen

Calculates TDCG and flags acetylene, hydrogen, ethylene and CO/CO₂ for expert classification.

ASTM D3612IEC 60567IEEE C57.104
Open and run →
Industrial OCM

Transformer Oil Furan Screen

Checks 2-FAL or an agreed total indicator as a marker of cellulose insulation ageing.

ASTM D5837IEC 61198
Open and run →
Industrial OCM

Transformer Oil Interfacial Tension

Checks IFT against limits configured for transformer oil type and age.

ASTM D971IEC 62961
Open and run →
Industrial OCM

Transformer Oil PCB Screen

Compares measured PCB concentration with applicable regulatory or contractual limits.

Open and run →
Industrial OCM

Transformer TDCG Generation Rate

Calculates TDCG increase in ppm/day between two consecutive DGA samples.

IEEE C57.104IEC 60599
Open and run →
Industrial OCM

Turbine Oil Air Release

Checks entrained-air release time against configured limits.

ASTM D3427ISO 9120
Open and run →
Industrial OCM

Turbine Oil Demulsibility

Checks oil/water separation time against configured limits.

ASTM D1401ISO 6614
Open and run →
Industrial OCM

Turbine Oil Health

Screens TAN, RPVOT retention, RULER, MPC and water for turbine-oil systems.

ASTM D664ASTM D2272ASTM D6971
Open and run →
Industrial OCM

Viscosity Index Retention

Compares in-service viscosity index with the baseline and flags material loss.

ASTM D2270
Open and run →
Industrial OCM

Wear Debris Microscopy Severity

Aggregates entered particle-category counts to prioritize expert morphology review.

ASTM D7684-24ASTM D7690-24
Open and run →