Industrial OCM · wear-debris-microscopy-severity
Wear Debris Microscopy Severity
Aggregates entered particle-category counts to prioritize expert morphology review.
Where to use
Gearboxes, bearings, circulating systems and abnormal-wear investigations.
Methodology
Uses microscopic-analysis categories in ASTM D7684/D7690 context; alarm thresholds are configured by the laboratory/OCM programme.
Standards context
Measurement
Console version
WearDebrisMicroscopySeverity.exe input.csv output.json
CSV header: severe_wear_count,fatigue_particle_count,cutting_particle_count,contaminant_particle_count,warning_total,critical_total
Limitations
This screening result uses user/OEM/laboratory limits and is not a universal normative limit. Interpret it with the trend, test method and actual condition of the specific asset. Particle morphology and qualified expert interpretation are more important than the simple total.