FUZKK AUTO OCM
RUEN
Industrial OCM · turbine-oil-health

Turbine Oil Health

Screens TAN, RPVOT retention, RULER, MPC and water for turbine-oil systems.

Where to use

Screens TAN, RPVOT retention, RULER, MPC and water for turbine-oil systems.

Methodology

Normalizes submitted data, calculates derived indicators and applies transparent warning rules.

Standards context

ASTM D664 ASTM D2272 ASTM D6971 ASTM D7843 ASTM D6304

Console version

TurbineOilHealth.exe input.csv output.json

CSV header: tan_growth,rpot_retention,ruler_retention,mpc,water_ppm

Limitations

This screening result does not replace manufacturer requirements, an accredited laboratory report or engineering diagnostics. Limits must be configured for the engine, lubricant, method and asset history.