Statistical Alarm Distance
Calculates absolute deviation from the configured baseline centre in sigma units for transparent statistical screening.
Where to use
Homogeneous fleets and stable laboratory series where centre and standard deviation are already established.
Methodology
A simplified z-distance indicator in ASTM D7720 context. ASTM D7720 itself is broader and addresses statistical evaluation of alarm limits.
Standards context
Console version
StatisticalAlarmDistance.exe input.csv output.json
CSV header: current_value,center_value,sigma,warning_sigma,critical_sigma
This screening result uses user/OEM/laboratory limits and is not a universal normative limit. Interpret it with the trend, test method and actual condition of the specific asset. It does not replace the full ASTM D7720 statistical procedure and requires a valid baseline.